♦ Minimum circulating volume: 800ml;
♦ Filter area: 0.4m2/set;
♦ Material tank: ≤ 50L;
♦ Working pressure: 0-6.5MPa;
♦ Allowable working temperature: 5-55 ℃ (depending on the membrane core);
♦ Pump power: 1.5KW;
♦ PH applicable range: 2-12 (depending on the membrane core);
♦ Filtration rate: 0.5-10L/H (depending on material and membrane core);
♦ Distribution box: explosion-proof distribution 220V;
♦ Equipment size: 1380 (length) × 670 (width) × 1050 (height) mm;
The organic membrane separation experimental machine (BONA-GM-18HE) can be equipped with various roll membrane components such as microfiltration, ultrafiltration, and nanofiltration. Widely used in fields such as biology, pharmaceuticals, food, chemicals, environmental protection, etc., for process experiments such as concentration, separation, purification, clarification, sterilization, desalination, and solvent removal of feed liquids; The selected experimental parameters of this equipment can be directly scaled up to pilot and industrial production; Bona Biotechnology, with its strong technical strength and professional technical services, fully guarantees the success rate of customers' experiments and has become the choice of laboratory membrane filtration equipment.
1. There are no welding points in the pipeline where the equipment and materials come into contact, ensuring the equipment's pressure resistance and corrosion resistance. Easy to operate, clean and hygienic, safe and reliable.
2. The equipment power supply adopts frequency conversion control, which can fully ensure the safety of equipment and personnel.
3. The material pump adopts a pressure protection system, which can achieve automatic overpressure relief protection and ensure absolute safety during the experimental process.
4. The material pump adopts a temperature sensing system, which can achieve automatic power outage protection over temperature, ensuring the stability of the material during the experimental process.
5. The membrane shell can ensure the flow rate of the membrane surface, ensure the safety of the experiment, and ensure the reliability and stability of the test data based on fluid dynamics.
6. The thickened design of the membrane shell allows for the replacement of membrane cores such as microfiltration membranes, ultrafiltration membranes, and nanofiltration membranes. Suitable for small scale separation experiments.
One imported plunger pump, one material tank, one set of pre filter, one SUS316L stainless steel membrane component, one pressure gauge, one temperature gauge, one flow meter, one heat exchanger, one accumulator, one pressure sensor, one temperature sensor, two pressure regulating valves, one basic electrical cabinet, one explosion-proof control cabinet, equipment support, connecting clamps, pipelines and their connectors, and one set of overpressure automatic protection system, One set of overtemperature automatic protection system, one set of variable frequency control system, and one membrane element.
Sterilization, clarification, and filtration of soy sauce, vinegar, etc
Removal of Impurities in Monosodium Glutamate Mother Liquor
Removal of impurities such as glucose crystallization mother liquor
Separation and purification of oligosaccharides and starch sugars
Fruit juice concentration and separation, plant extraction
Clarification and filtration of animal and plant extracts
Desalination and Concentration of Antibiotic Resin Analysis Solution
Vitamin concentration
Desalination concentration, replacing salting out and acid precipitation
Amino acids, decolorization and impurity removal, concentration, desalination
Complete multiple membrane equipment
Engineers with membrane engineering
Professional technical support provided
A comprehensive customer service system
Provide high-quality maintenance services